Evident LogoOlympus Logo
Material didáctico
Notas de aplicación
Regresar al material didáctico

Laterally Focused Arrays-Improved Defect Length Sizing


Automatic Fastener Hole inspection in Aircraft Overview

Improvements in probe manufacturing technology have led to improved defect length sizing. Phased Array CCEV [Concave Curvature in Elevation (axis)] probes have been created to improve accuracy in defect length sizing. Two primary applications, small diameter piping and onshore/offshore pipeline construction have been the primary applications where this technology has been exploited but many phased array users are applying them in other applications. This technology has led to improve difficult small diameter thin wall inspections as well as critical pipeline inspections.

CCEV Phased Array Probes Construction

Phased Array probes can be electronically focused in the forward or active axis by controlling the pulse and reception of the elements. Without complex array construction (dual/matrix array etc.) the passive axis has long been left to natural beam spread created by aperture and element dimensions and frequency of the probe. CCEV probes were created by applying a curvature in the elevation or side to side or passive axis dimension of a phased array probe. The appropriate curvature was established by laboratory trials and simulated beam simulations for the typical diameters and wall thickness for both pipeline construction welds and small diameter pipe and tube welds. Similar to applying a lens to an immersion probe the effect is a smaller beam spot width, which can lessen beam spread effects and allow better length sizing potential. Although primarily applied to the PipeWIZARD and COBRA scanning systems, the technology can be applied to almost any linear array probe design to fit other applications. An internal integrated lens allows the use of standard flat wedges and flat outside casing.

linearinternal focus
flatcurved

Illustration of flat and internally focused arrays with corresponding beam plot. Note significantly reduced beam width.

Results from PipeWizard System on 3mm wide reflector with normal 1D linear Flat Array and CCEV Curved Probe.Results from PipeWizard System on 3mm wide reflector with normal 1D linear Flat Array and CCEV Curved Probe.
Results from PipeWizard System on 3mm wide reflector with normal 1D linear Flat Array and CCEV Curved Probe.Results from PipeWizard System on 3mm wide reflector with normal 1D linear Flat Array and CCEV Curved Probe.

Results from PipeWIZARD System on 3mm wide reflector with normal 1D linear Flat Array and CCEV Curved Probe.

Results of inspection on 2.75” (70mm) dia. Pipe with induced 6.9mm x .5mm OD notch. Note signifigant sharpness of data and improved sizing using CCEV probe. Data taken utilizing Cobra Scanner. Sizing done via – 6dB drop method.
Results of inspection on 2.75” (70mm) dia. Pipe with induced 6.9mm x .5mm OD notch. Note signifigant sharpness of data and improved sizing using CCEV probe. Data taken utilizing COBRA Scanner. Sizing done via – 6dB drop method.

Cobra Semi-Automatic Scanner for Small Diameter Pipe and Tube and PipeWizard Automated System for Pipeline Construction. CCEV probes have been optimized for use in these two systems.Cobra Semi-Automatic Scanner for Small Diameter Pipe and Tube and PipeWizard Automated System for Pipeline Construction. CCEV probes have been optimized for use in these two systems.

COBRA Semi-Automatic Scanner for Small Diameter Pipe and Tube and PipeWIZARD Automated System for Pipeline Construction. CCEV probes have been optimized for use in these two systems.

Conclusion

Laterally focused arrays have been created significantly improving length sizing potential in small diameter piping and pipeline construction systems. This technology can be applied to most 1D linear array probes, offering potential to improve sizing in many often performed phased array examinations. Standard CCEV arrays are listed in our phased array probe catalog.

Please contact SCE.PM@olympusndt.com or submit details via our online custom probe form to ask about custom CCEV probe possibilities for your applications.

Olympus IMS

Productos para la aplicación
Este equipo ligero de un solo canal proporciona una pantalla táctil fácil de leer de 8,4" (21,3 cm) y soluciones bastante rentables en el plano precio-rendimiento. Viene en dos modelos: SX PA y SX UT. El modelo SX PA es una unidad 16:64PR que, al igual que el modelo SX UT [con un solo canal UT], también está equipado con una canal UT para inspecciones de pulso-eco (pulse-echo), emisión-recepción (pitch-catch) y TOFD.
Las sondas Phased Array para aplicaciones específicas se ofrecen una escala de frecuencias de 0,5 MHz a 18 MHz y vienen con 16, 32, 64 o 128 elementos. Las sondas especializadas pueden dotarse de hasta cientos de elementos.
El PipeWIZARD es un sistema de inspección para soldaduras circunferenciales que emplea las técnicas automatizadas de ultrasonido multielemento (PA) y ultrasonido convencional (UT). Está especialmente diseñado para la inspección de soldadura a soldadura in situ en ambientes hostiles, en tierra o mar adentro.
El escáner manual COBRA™, combinado con el detector de defectos OmniScan X3, es usado para efectuar inspecciones de soldaduras circunferenciales en tuberías de diámetro pequeño. La unidad de escaneo de diámetro pequeño COBRA es compatible hasta con dos sondas PA para inspeccionar tuberías con diámetros externos que van de 0,84 pulg. a 4,5 pulg.
Lo sentimos, la página solicitada no se encuentra disponible en su país.
Let us know what you're looking for by filling out the form below.
Lo sentimos, la página solicitada no se encuentra disponible en su país.