Specifications
Magnification [X]
|
5
|
---|
Numerical aperture (NA)
|
0.1
|
---|
Working distance (WD) [mm]
|
12
|
---|
Objective Field Number
|
22
|
---|
Immersion medium
|
Air/Dry
|
---|
Spring loaded
|
N/A
|
---|
Correction collar
|
N/A
|
---|
Correction range of correction collar
|
N/A
|
---|
Iris
|
N/A
|
---|
Correction level of chromatic aberration
|
Achromat (ACH)
|
---|
Parfocalizing distance [mm]
|
45
|
---|
Back focal plane (BFP) position
|
-
|
---|
Type of screw thread
|
W26X0.706
|
---|
Brightfield(Reflected)
|
Good
|
---|
Brightfield(Transmitted)
|
Good
|
---|
Darkfield(Reflected)
|
Good
|
---|
Darkfield(Transmitted)
|
N/A
|
---|
DIC(Reflected)
|
N/A
|
---|
DIC(Transmitted)
|
N/A
|
---|
Phase Contrast
|
N/A
|
---|
Relief Contrast
|
N/A
|
---|
Polarized Light
|
N/A
|
---|
Fluorescence (B, G Excitation)
|
N/A
|
---|
UV Fluorescence (at 365nm)
|
N/A
|
---|
Multiphoton
|
N/A
|
---|
TIRF
|
N/A
|
---|
IR
|
N/A
|
---|
WLI
|
N/A
|
---|
Auto Focus
|
N/A
|
---|
Transmittance/Wavelength
Dimensions
MPLN10xBD
Specifications
Magnification [X]
|
10
|
---|
Numerical aperture (NA)
|
0.25
|
---|
Working distance (WD) [mm]
|
6.5
|
---|
Objective Field Number
|
22
|
---|
Immersion medium
|
Air/Dry
|
---|
Spring loaded
|
N/A
|
---|
Correction collar
|
N/A
|
---|
Correction range of correction collar
|
N/A
|
---|
Iris
|
N/A
|
---|
Correction level of chromatic aberration
|
Achromat (ACH)
|
---|
Parfocalizing distance [mm]
|
45
|
---|
Back focal plane (BFP) position
|
-
|
---|
Type of screw thread
|
W26X0.706
|
---|
Brightfield(Reflected)
|
Good
|
---|
Brightfield(Transmitted)
|
Good
|
---|
Darkfield(Reflected)
|
Good
|
---|
Darkfield(Transmitted)
|
N/A
|
---|
DIC(Reflected)
|
N/A
|
---|
DIC(Transmitted)
|
N/A
|
---|
Phase Contrast
|
N/A
|
---|
Relief Contrast
|
N/A
|
---|
Polarized Light
|
N/A
|
---|
Fluorescence (B, G Excitation)
|
N/A
|
---|
UV Fluorescence (at 365nm)
|
N/A
|
---|
Multiphoton
|
N/A
|
---|
TIRF
|
N/A
|
---|
IR
|
N/A
|
---|
WLI
|
N/A
|
---|
Auto Focus
|
N/A
|
---|
Transmittance/Wavelength
Dimensions
MPLN20xBD
Specifications
Magnification [X]
|
20
|
---|
Numerical aperture (NA)
|
0.4
|
---|
Working distance (WD) [mm]
|
1.3
|
---|
Objective Field Number
|
22
|
---|
Immersion medium
|
Air/Dry
|
---|
Spring loaded
|
Yes
|
---|
Correction collar
|
N/A
|
---|
Correction range of correction collar
|
N/A
|
---|
Iris
|
N/A
|
---|
Correction level of chromatic aberration
|
Achromat (ACH)
|
---|
Parfocalizing distance [mm]
|
45
|
---|
Back focal plane (BFP) position
|
-
|
---|
Type of screw thread
|
W26X0.706
|
---|
Brightfield(Reflected)
|
Good
|
---|
Brightfield(Transmitted)
|
Good
|
---|
Darkfield(Reflected)
|
Good
|
---|
Darkfield(Transmitted)
|
N/A
|
---|
DIC(Reflected)
|
N/A
|
---|
DIC(Transmitted)
|
N/A
|
---|
Phase Contrast
|
N/A
|
---|
Relief Contrast
|
N/A
|
---|
Polarized Light
|
N/A
|
---|
Fluorescence (B, G Excitation)
|
N/A
|
---|
UV Fluorescence (at 365nm)
|
N/A
|
---|
Multiphoton
|
N/A
|
---|
TIRF
|
N/A
|
---|
IR
|
N/A
|
---|
WLI
|
N/A
|
---|
Auto Focus
|
N/A
|
---|
Transmittance/Wavelength
Dimensions
MPLN50xBD
Specifications
Magnification [X]
|
50
|
---|
Numerical aperture (NA)
|
0.75
|
---|
Working distance (WD) [mm]
|
0.38
|
---|
Objective Field Number
|
22
|
---|
Immersion medium
|
Air/Dry
|
---|
Spring loaded
|
Yes
|
---|
Correction collar
|
N/A
|
---|
Correction range of correction collar
|
N/A
|
---|
Iris
|
N/A
|
---|
Correction level of chromatic aberration
|
Achromat (ACH)
|
---|
Parfocalizing distance [mm]
|
45
|
---|
Back focal plane (BFP) position
|
-
|
---|
Type of screw thread
|
W26X0.706
|
---|
Brightfield(Reflected)
|
Good
|
---|
Brightfield(Transmitted)
|
Good
|
---|
Darkfield(Reflected)
|
Good
|
---|
Darkfield(Transmitted)
|
N/A
|
---|
DIC(Reflected)
|
N/A
|
---|
DIC(Transmitted)
|
N/A
|
---|
Phase Contrast
|
N/A
|
---|
Relief Contrast
|
N/A
|
---|
Polarized Light
|
N/A
|
---|
Fluorescence (B, G Excitation)
|
N/A
|
---|
UV Fluorescence (at 365nm)
|
N/A
|
---|
Multiphoton
|
N/A
|
---|
TIRF
|
N/A
|
---|
IR
|
N/A
|
---|
WLI
|
N/A
|
---|
Auto Focus
|
N/A
|
---|
Transmittance/Wavelength
Dimensions
MPLN100xBD
Specifications
Magnification [X]
|
100
|
---|
Numerical aperture (NA)
|
0.9
|
---|
Working distance (WD) [mm]
|
0.21
|
---|
Objective Field Number
|
22
|
---|
Immersion medium
|
Air/Dry
|
---|
Spring loaded
|
Yes
|
---|
Correction collar
|
N/A
|
---|
Correction range of correction collar
|
N/A
|
---|
Iris
|
N/A
|
---|
Correction level of chromatic aberration
|
Achromat (ACH)
|
---|
Parfocalizing distance [mm]
|
45
|
---|
Back focal plane (BFP) position
|
-
|
---|
Type of screw thread
|
W26X0.706
|
---|
Brightfield(Reflected)
|
Good
|
---|
Brightfield(Transmitted)
|
Good
|
---|
Darkfield(Reflected)
|
Good
|
---|
Darkfield(Transmitted)
|
N/A
|
---|
DIC(Reflected)
|
N/A
|
---|
DIC(Transmitted)
|
N/A
|
---|
Phase Contrast
|
N/A
|
---|
Relief Contrast
|
N/A
|
---|
Polarized Light
|
N/A
|
---|
Fluorescence (B, G Excitation)
|
N/A
|
---|
UV Fluorescence (at 365nm)
|
N/A
|
---|
Multiphoton
|
N/A
|
---|
TIRF
|
N/A
|
---|
IR
|
N/A
|
---|
WLI
|
N/A
|
---|
Auto Focus
|
N/A
|
---|
Transmittance/Wavelength
Dimensions